Product name: | Photoelectric direct reading liquid seal valve con |
Category: | Photoelectric Direct Reading remote meter |
Product model: | LXSKY-15~25 |
Name: LXSYY-15E ~ 50E rotor photoelectric direct reading liquid sealed VRLA remote meter
Uses: This series of water meter for drinking water usage. Residents (sub-table) or industrial use.
Conditions of Use:
Temperature class: T30
Pressure Level: MAP 10 / MAP 16
Pressure loss rating: △ P 63
Indication error limit:
From minimum flow (Q1) to excluding transitional flow (Q2) of the lower zone ± 5%
From the high zone of the transitional flow (Q2) to overload flow (Q4) of ± 2%
Characteristics and main technical parameters:
Multi-streaming technology;
Horizontal mounting, measuring range R = 80
Digital counter wheel with special liquid package, long-term clear reading
Movement, using high-quality materials, long life, stable and reliable performance, external adjustment (seal); ductile iron or copper shell case (Case spray)
Direct-reading Valve Control module uses photoelectric direct reading technology to read data word round, compared with the conventional pulse table, it can be reduced to zero reading error, AMR metering system is ideal zero error product. Module uses low-power design, usually no power supply, only when the meter readings and conduct valve switch its power needs. The module can be installed directly in the base table counter, assembled into remote base table VRLA photoelectric direct reading table, with the smart metering system equipment, complete intelligent reading copy cell data and remote meter control valve on / off, and Implementation and settlement center networking data sharing.
一、Features
1, reading the word round of data, compared with the conventional pulse table, it can be reduced to zero reading error;
2, low-power design, and only if the readings valve switch supplied with power;
3, the use of advanced data encoding and verification technology, high reliability communications;
4, in line with "electronic remote meter" (CJ / T 224-2012) standard;
5, compatible with a variety of communication protocols; DL / T645, CJ / T188 and internal protocols;
6, to meet the EMC, ESD, EMI and other electronic products, electromagnetic compatibility design requirements, to achieve industry-leading level;
7, combined with the host computer system, to establish a remote automatic meter reading management system, the real meter reading, monitoring automation.
二、Second, the technical parameters
2, working voltage: DC 36V;
3, the working current:
Current meter reading ≤9.0mA
Quiescent current ≤1.3 mA
Valve On / Off Bus Current ≤50 mA (reference value, the valve will be different depending on the difference)
Valve open / close valve motor input current ≤30 mA (reference value, the valve will be different depending on the difference)
4, the working environment: temperature: -10 ℃ ~ + 45 ℃ Humidity: 0 ~ 95% RH;
5, Storage temperature: -25 ℃ ~ + 65 ℃;
6, with the host computer communication: M-bus field bus;
7, communication transmission speed: 2400 baud;
8, communication protocol: DL / T645, CJ / T 188 and an internal protocol (or user-specified statute);
9, the maximum transmission distance communication: 300m; (communication line specification AVVR2 × 0.75)
10, the bus pin ESD protection exceeding 10kV;
11, the short-circuit current protection;
12, for the bus open, short, idle fault protection.
The main technical parameters:
caliber DNmm | Measuring range Q3/Q1 | Traffic overload Q4 | Common flow Q3 | Transitional Flow Q2 | Minimum flow Q1 | Starting flow | Minimum reading | The maximum reading |
m3/h | L/h | m3 | ||||||
15 | 80 | 3.125 | 2.5 | 50 | 31.25 | 12 | 0.00005 | 99999 |
100 | 40 | 25 | ||||||
160 | 25 | 15.625 | 5 | |||||
200 | 20 | 12.5 | ||||||
20 | 80 | 5 | 4 | 80 | 50 | 16 | ||
100 | 64 | 40 | ||||||
160 | 40 | 25 | 6 | |||||
200 | 32 | 20 | ||||||
25 | 80 | 7.875 | 126 | 78.75 | 17 | |||
100 | 100.8 | 63 | ||||||
160 | 63 | 39.375 | 8 | |||||
200 | 50.4 | 31.5 | ||||||
32 | 80 | 12.5 | 10 | 200 | 125 | 23 | ||
100 | 160 | 100 | ||||||
160 | 100 | 62.5 | 10 | |||||
200 | 80 | 50 | ||||||
40 | 80 | 20 | 16 | 320 | 200 | 50 | ||
100 | 256 | 160 | ||||||
160 | 160 | 100 | 35 | |||||
200 | 128 | 80 | ||||||
50 | 80 | 31.25 | 25 | 500 | 312.5 | 60 | ||
100 | 400 | 250 | ||||||
160 | 250 | 156.25 | 40 | |||||
200 | 200 | 125 |
● flow error curve
● Pressure loss curve
● Dimensions and weight
Nominal diameter | long L | width B | high H | Connection thread (D) | weight(kg) |
(mm) | mm | ||||
15 | 165/190 | 99 | 104 | G3/4B | 1.5/1.6 |
20 | 190/195 | 99 | 106 | G1B | 1.7 |
25 | 260/225 | 104 | 120 | G1 1/4B | 2.6/2.4 |
32 | 260/230 | 104 | 120 | G1 1/2B | 2.8/2.7 |
40 | 300/245 | 125 | 155 | G2B | 5.4/4.5 |
50 | 300 | 125 | 155 | B2 1/2B | 7.2 |
280 | 158 | 175 | Flanged Press GB4216.4.84 D=165 D1=125 | 14 |
● Conditions of Use
Working temperature no higher than 40 °c
Working pressure is less than 1MPa