欧美日韩福利视频一区二区三区,久久99精品久久久久久无毒不卡,久久久久亚洲,国产欧美精品一区二区三区四区,日韩欧美精品一区二区永久在线

Products Home Page > Smart meter > Photoelectric Direct Reading remote meter > Photoelectric Direct Reading dry VRLA table
Photoelectric Direct Reading dry VRLA table
  • Photoelectric Direct Reading dry VRLA table
  • Product name:

    Photoelectric Direct Reading dry VRLA table

    Category: Photoelectric Direct Reading remote meter
    Product model: LXSGKY-15~25
Product details

Name: LXSYY-15E ~ 50E rotor photoelectric direct reading liquid sealed VRLA remote meter


Uses: This series of water meter for drinking water usage. Residents (sub-table) or industrial use.


Conditions of Use:

Temperature class: T30

Pressure Level: MAP 10 / MAP 16

Pressure loss rating: △ P 63

Indication error limit:

From minimum flow (Q1) to excluding transitional flow (Q2) of the lower zone ± 5%

From the high zone of the transitional flow (Q2) to overload flow (Q4) of ± 2%


Characteristics and main technical parameters:

Multi-streaming technology;

Horizontal mounting, measuring range R = 80

Digital counter wheel with special liquid package, long-term clear reading

Movement, using high-quality materials, long life, stable and reliable performance, external adjustment (seal); ductile iron or copper shell case (Case spray)

Direct-reading Valve Control module uses photoelectric direct reading technology to read data word round, compared with the conventional pulse table, it can be reduced to zero reading error, AMR metering system is ideal zero error product. Module uses low-power design, usually no power supply, only when the meter readings and conduct valve switch its power needs. The module can be installed directly in the base table counter, assembled into remote base table VRLA photoelectric direct reading table, with the smart metering system equipment, complete intelligent reading copy cell data and remote meter control valve on / off, and Implementation and settlement center networking data sharing.


一、Features

1, reading the word round of data, compared with the conventional pulse table, it can be reduced to zero reading error;

2, low-power design, and only if the readings valve switch supplied with power;

3, the use of advanced data encoding and verification technology, high reliability communications;

4, in line with "electronic remote meter" (CJ / T 224-2012) standard;

5, compatible with a variety of communication protocols; DL / T645, CJ / T188 and internal protocols;

6, to meet the EMC, ESD, EMI and other electronic products, electromagnetic compatibility design requirements, to achieve industry-leading level;

7, combined with the host computer system, to establish a remote automatic meter reading management system, the real meter reading, monitoring automation.


二、Second, the technical parameters

2, working voltage: DC 36V;

3, the working current:

Current meter reading ≤9.0mA

Quiescent current ≤1.3 mA

Valve On / Off Bus Current ≤50 mA (reference value, the valve will be different depending on the difference)

Valve open / close valve motor input current ≤30 mA (reference value, the valve will be different depending on the difference)

4, the working environment: temperature: -10 ℃ ~ + 45 ℃ Humidity: 0 ~ 95% RH;

5, Storage temperature: -25 ℃ ~ + 65 ℃;

6, with the host computer communication: M-bus field bus;

7, communication transmission speed: 2400 baud;

8, communication protocol: DL / T645, CJ / T 188 and an internal protocol (or user-specified statute);

9, the maximum transmission distance communication: 300m; (communication line specification AVVR2 × 0.75)

10, the bus pin ESD protection exceeding 10kV;

11, the short-circuit current protection;

12, for the bus open, short, idle fault protection.


The main technical parameters:

caliber DNmmMeasuring range Q3/Q1Traffic overload Q4Common flow Q3Transitional Flow Q2Minimum flow Q1Starting flowMinimum readingThe maximum reading
m3/hL/hm3
15803.1252.55031.25120.0000599999
1004025
1602515.6255
2002012.5
208054805016
1006440
16040256
2003220
25807.87512678.7517
100100.863
1606339.3758
20050.431.5
328012.51020012523
100160100
16010062.510
2008050
4080201632020050
100256160
16016010035
20012880
508031.2525500312.560
100400250
160250156.2540
200200125


● flow error curve


● Pressure loss curve


● Dimensions and weight

Nominal diameterlong Lwidth Bhigh HConnection thread (D)weight(kg)
(mm)mm
15165/19099104G3/4B1.5/1.6
20190/19599106G1B1.7
25260/225104120G1 1/4B2.6/2.4
32260/230104120G1 1/2B2.8/2.7
40300/245125155G2B5.4/4.5
50300125155B2 1/2B7.2
280158175Flanged Press GB4216.4.84 D=165 D1=12514




● Conditions of Use

Working temperature no higher than 40 °c

Working pressure is less than 1MPa


Ningbo Shengde WaterMeter Co.,Ltd.Reserved.code

Adderss:Xin'an lndustry Zone, Xijiao, Ningbo, China Tel:+86-0574-88440229 Sales dep tel:

Contact person: Purchasing dep tel: E-mail:76412366@qq.com Zip:315101

Copyright ? Sunway Hanguang Electric Manufacturing Limited